Connector Types
Type | Reference | Note | |
LC | IEC 61754-20 | Single Mode Duplex | APC: Green connectors UPC: Blue connectors |
Multimode Duplex | UPC: Grey connectors |
1. NSN boot 180° duplex LC Fiber Optic Jumper
2. NSN boot 90° duplex LC Fiber Optic Jumper
Patch Cord Versions
Jumper Tolerance Requirement | |
Overall Length (L) (M) | Length of Tolerance (CM) |
0<L<20 | +10/-0 |
20<L<40 | +15/-0 |
L>40 | +0.5%L/-0 |
Cable Parameters
Cable
Count |
Out Sheath Diameter (MM) | Weight
(KG) |
Minimum Allowable Tensile Strength (N) | Minimum Allowable Crush Load (N/100mm) | Minimum Bending Radius (MM) | Storage
Temperature (°C) |
|||
Short Term | Long Term | Short Term | Long Term | Short Term | Long Term | ||||
2 | 5.0±0.2 | 30 | 800 | 400 | 2000 | 1000 | 20D | 10D | -20 ~~ +70 |
Cable Structure
Cable Parameters
Cable
Count |
Out sheath Diameter (MM) | Weight
(KG) |
Minimum Allowable Tensile Strength (N) | Minimum Allowable Crush Load (N/100mm) | Minimum Bending Radius (MM) | Storage
Temperature (°C) |
|||
Short Term | Long Term | Short Term | Long Term | Short Term | Long Term | ||||
2 | 5.0±0.2 | 45 | 400 | 800 | 2000 | 3000 | 20D | 10D | -20—+70 |
Cable Structure
Cable Parameters
Cable
Count |
Out sheath Diameter (MM) | Weight
(KG) |
Minimum Allowable Tensile Strength (N) | Minimum Allowable Crush Load
(N/100mm) |
Minimum Bending Radius (MM) | Storage
Temperature (C) |
|||
Short Term | Long Term | Short Term | Long Term | Short Term | Long Term | ||||
2 | 7.0±0.3 | 68 | 600 | 1000 | 2000 | 3000 | 20D | 10D | -20—+70 |
Cable Structure
Cable Parameters
Cable
Count |
Out sheath Diameter (MM) | Weight
(KG) |
Minimum Allowable Tensile Strength (N) | Minimum Allowable Crush Load (N/100mm) | Minimum Bending Radius (MM) | Storage
Temperature (°C) |
|||
Short Term | Long Term | Short Term | Long Term | Short Term | Long Term | ||||
2 | 7 0±0 3mm | 50 | 600 | 1000 | 1000 | 2000 | 20D | 10D | -20—+70 |
Optical Characteristics
Item | Parameter | Reference | |
Single Mode | Multimode | ||
Insertion Loss | Typical Value<0.15dB;Maximum<0.30 | Typical Value<0.15dB;Maximum<0.30 | IEC 61300-3-34 |
Return Loss | ^ 60dB(APC); ^ 50dB (UPC) | ^30dB (UPC) | IEC 61300-3-6 |
End-Face Geometry
Item | UPC (Ref: IEC 61755-3-1) | APC (Ref: IEC 61755-3-2) |
Radius of Curvature (mm) | 7 to 25 | 5 to 12 |
Fiber Height (nm) | -100 to 100 | -100 to 100 |
Apex Offset (^m) | 0 to 50 | 0 to 50 |
APC Angle (°) | / | 8° ±0.2° |
Key Error (°) | / | 0.2° max |
End-Face Quality
Zone | Range (^m) | Scratches | Defects | Reference |
A: Core | 0 to 25 | None | None | IEC 61300-3-35:2015 |
B: Cladding | 25 to 115 | None | None | |
C: Adhesive | 115 to 135 | None | None | |
D: Contact | 135 to 250 | None | None | |
E: Rest of ferrule | None | None |
End Face Quality (MM)
Zone | Range (^m) | Scratches | Defects | Reference |
A: Core | 0 to 65 | None | None | IEC 61300-3-35:2015 |
B: Cladding | 65 to 115 | None | None | |
C: Adhesive | 115 to 135 | None | None | |
D: Contact | 135 to 250 | None | None | |
E: Rest of ferrule | None | None |
Mechanical Characteristics
Test | Conditions | Reference |
Endurance | 500 matings | IEC 61300-2-2 |
Vibration | Frequency: 10 to 55Hz, Amplitude: 0.75mm | IEC 61300-2-1 |
Cable Retention | 400N (main cable); 50N (connector part) | IEC 61300-2-4 |
Strength of Coupling Mechanism | 80N for 2 to 3mm cable | IEC 61300-2-6 |
Cable Torsion | 15N for 2 to 3mm cable | IEC 61300-2-5 |
Fall | 10 drops, 1m drop height | IEC 61300-2-12 |
Static Lateral Load | 1N for 1h (main cable); 0.2N for 5min (ranch part) | IEC 61300-2-42 |
Cold | -25°C, 96h duration | IEC 61300-2-17 |
Dry Heat | +70°C, 96h duration | IEC 61300-2-18 |
Change of Temperature | -25°C to +70°C, 12 cycles | IEC 61300-2-22 |
Humidity | +40°C at 93%, 96h duration | IEC 61300-2-19 |
● Multi-purpose Outdoor.
● For connection between distribution box and RRH.
● Deployment in Remote Radio Head cell tower applications.