Application
Characteristics
Standards
GJFJV cable complies with Standard YD/T1258.2-2009、ICEA-596、GR-409、IEC794 etc; and meets with the requirements of UL approval for OFNR and OFNP.
Cable Code
MPC-02 |
MPC-04 |
MPC-06 |
MPC-08 | MPC-10 |
MPC-12 |
|
Cable Diameter(mm) |
4.1±0.25 |
4.8±0.25 |
5.1±0.25 |
6.2±0.25 | 6.5±0.25 |
6.8±0.25 |
Cable Weight(kg/km) |
12 |
20 |
24 |
29 |
32 |
35 |
Tight Buffer Fiber Diameter | 900±50μm |
Optical Characteristics
G.652 | G.657 | 50/125um | 62.5/125um | ||
Attenuation (+20℃) |
@ 850nm | ≤3.0 dB/km | ≤3.0 dB/km | ||
@ 1300nm | ≤1.0 dB/km | ≤1.0 dB/km | |||
@ 1310nm | ≤0.36 dB/km | ≤0.36 dB/km | |||
@ 1550nm | ≤0.22 dB/km | ≤0.23 dB/km | |||
Bandwidth (Class A)@850nm |
@ 850nm | ≥500 Mhz.km | ≥500 Mhz.km | ||
@ 1300nm | ≥1000 Mhz.km | ≥600 Mhz.km | |||
Numerical aperture | 0.200±0.015NA | 0.275±0.015NA | |||
Cable Cutoff Wavelength | ≤1260nm | ≤1480nm |
Technical Parameters
Tensile Strength |
Long-term |
80N |
60N |
50N |
Short-term |
150N |
120N |
100N | |
Crush Resistance |
Long-term |
100N/100mm |
100N/100mm |
100N/100mm |
Short-term |
500N/100mm |
500N/100mm |
500N/100mm |
|
Bending Radius |
Dynamic |
20xD |
20xD |
20xD |
Static |
10xD |
10xD |
10xD |
Environmental Characteristics
Transport Temperature |
-20℃~+60℃ |
Installation Temperature |
-5℃~+50℃ |
Storage Temperature |
-20℃~+60℃ |
Operating Temperature |
-20℃~+60℃ |